The new Accucore™ C8 HPLC column is based on state-of-the-art Core Enhanced Technology™. It expands the Accucore HPLC family of columns with a shorter alkyl length bonded phase, which provides lower hydrophobic retention than the equivalent C18 phase. The new phase enhances chromatographic performance without generating excessive operating pressure, enabling laboratories to improve sample throughput and quality of results. Compatible with any instrument from any manufacturer, the Accucore C8 HPLC column is recommended for analytes with medium hydrophobicity
Acclaim™ Surfactant Plus columns are designed for high-resolution, high-efficiency and high-throughput single run separation of different types of surfactants, including nonionic, anionic, cationic and amphoteric, that are widely used in pesticides, detergents, petroleum products, cosmetics and pharmaceuticals. The Acclaim Surfactant Plus columns are based on a novel bonding chemistry that results in higher selectivity. The advanced surface modification process is designed to provide column-to-column consistency and a hydrolytically stable and reproducible surface, resulting in excellent compatibility with a Corona Charged Aerosol Detector, mass spectrometer (MS) or evaporative light scattering detector (ELSD).
The new smaller-particle sized MAbPac™ SCX-10 columns, available in 3 μm and 5 μm particle sizes, are used for separation of closely related monoclonal antibody variants, even those that differ by as little as one charged residue. The new columns provide high-resolution separations, similar to the 10 µm size column and the Thermo Scientific ProPac WCX-10 4 x 250mm columns, but offer significantly faster analysis and shorter separation times, all with excellent column-to-column and lot-to-lot reproducibility. Additionally, a pH gradient can be used for rapid, high-throughput analysis of monoclonal antibody samples with varying iso-electric points.
Thermo Scientific SOLA solid phase extraction (SPE) cartridges and plates utilize a proprietary design and manufacturing technique that combines polyethylene frit materials and stationary phase components into one, uniform entity. As a result, SOLA™ cartridges and plates deliver superior reproducibility, lower elution volumes, increased sensitivity and reduce the levels of contaminants and extractables within the sample eluate.
The design provided by SOLA cartridges and plates is a significant advancement on traditional SPE formats and eliminates issues such as voiding, channeling and packing inconsistencies. This provides analysts with highly reproducible results the first time, every time, with consistency from cartridge to cartridge, box to box and batch to batch. This means fewer failures and prevents costly re-analysis. As a result, SOLA cartridges and plates address key requirements for today’s and tomorrow’s high-throughput laboratory environments.
Thermo Scientific Titan3 and Target2 syringe filters feature a new robust design, delivering greater burst pressures and exceptional flow-through characteristics that significantly enhance sample preparation workflows. Both the Titan3™ and Target2™ syringe filter ranges are fully HPLC tested and incorporate low extractable membranes and housings. In addition, the new design holds the membrane in place more effectively, optimizing the available surface area for more efficient filtration. The premium Titan3 range provides further confidence with color-coded integral rings for easy membrane selection, and it provides greater burst pressures, with 30mm models resistant to pressures of up to 120 psi.
The new columns and consumables are available in the 2012-2013 Thermo Scientific Chromatography Columns and Consumables catalog. The catalog, which is organized into four core segments – sample preparation, vials and closures, gas chromatography and liquid chromatography – combines all the latest product innovations, including those from the recently acquired Dionex ranges, into a single, extensive portfolio. For the first time, the catalog also includes instruments such as the Thermo Scientific Dionex AutoTrace 280 automated SPE workstation and the Thermo Scientific Dionex ICS-900 integrated single channel ion chromatography system. To order the catalog, available in hardcopy or electronically, please visit: www.thermoscientific.com/catalog.
For more information about new Thermo Scientific chromatography columns and consumables or the new catalog, please call +1 866-463-6522 or email analyze@thermofisher.com.
For access to all Thermo Fisher news and product photos related to ASMS 2012, please visit the online media room at www.thermofisher.com/news.
About Thermo Fisher Scientific
Thermo Fisher Scientific Inc. is the world leader in serving science. Our mission is to enable our customers to make the world healthier, cleaner and safer. With revenues of $12 billion, we have approximately 39,000 employees and serve customers within pharmaceutical and biotech companies, hospitals and clinical diagnostic labs, universities, research institutions and government agencies, as well as in environmental and process control industries. We create value for our key stakeholders through three premier brands, Thermo Scientific, Fisher Scientific and Unity™ Lab Services, which offer a unique combination of innovative technologies, convenient purchasing options and a single solution for laboratory operations management. Our products and services help our customers solve complex analytical challenges, improve patient diagnostics and increase laboratory productivity. Visit http://www.thermofisher.com.
Contact:
Thermo Fisher Scientific Inc.
Stephanie Kubina, +1-408-965-6022
stephanie.kubina@thermofisher.com